Product Details
Customization: Available
Appearance And Structure: Integral
Function of Measurement: Classical Total Station
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
ODM Services
The supplier provides ODM services
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (10)
  • Trimble C5 Engineering Surveying Total Station
  • Trimble C5 Engineering Surveying Total Station
  • Trimble C5 Engineering Surveying Total Station
  • Trimble C5 Engineering Surveying Total Station
  • Trimble C5 Engineering Surveying Total Station
  • Trimble C5 Engineering Surveying Total Station
Find Similar Products

Basic Info.

Model NO.
Trimble C5
Range Finding
3-15km
Test Range
5,000 M
Amplfication
30X
Distance Accuracy
1+1.5ppm
Angle Measurement Accuracy
1"
Processing Customization
No
High Speed Range
Yes
Prism-Free Accuracy
2 + 2ppm
Prism-Free Ranging Time
0.3-1 Second
Prism Ranging Time
0.3-1 Second
Tilting Sensor
Biaxis
Communication Mode
USB and Bluetooth
Power Supply Voltage
3.6V
Working Hours
7-19 Hours
Charging Time
6 Hours
Automatic Focus
Yes
Transport Package
Boxed
Specification
4.5kg
Trademark
Trimble
Origin
America
Production Capacity
1000

Packaging & Delivery

Package Size
100.00cm * 100.00cm * 100.00cm
Package Gross Weight
10.000kg

Product Description

Trimble C5 Color screen intelligent full station instrument
Trimble C5 Full station system has a robust, reliable and humanized design. It allows users to easily complete tasks, even under more complex field conditions. In projects in different environments around the world, C5 works efficiently, quickly obtaining accurate measurements and virtually eliminating downtime.
Trimble C5 Easy to operate
Autofocus enables the C5 to focus quickly and accurately on the expected distance, so that the user can simply see, measure, and leave. Even in low-light conditions, the superior optical systems give you clear, bright visions. The accurate and true results obtained ensure the work efficiency of the whole project.
1.Autofocus function can ensure accurate and fast focus
2.Strong and efficient long-range EDM
3.Double color touch display mirror
4.L2P safe position technology
5.Compact, light, robust system design


Works efficiently and accurately
The new Trimble C5 mechanical full station, which improves the production capacity and saves time, makes the field work easier and faster. It refines the industry's product portfolio. Trimble C5 Durable, high reliability, is a user-friendly design. Even with difficult site conditions, it can withstand and reduce user fatigue. Across a wide variety of projects, the C5 operates at high intensity, quickly capturing accurate measurements with almost no downtime.
Accurate autofocus, excellent quality optical lens, and accurate results
Trimble C5 Set as simple as Trimble users expect. Nikon's autofocus allows the C5 to focus quickly and accurately within the expected distance, requiring the user to aim and then move to the next location. This means high productivity on any other day. Even in dim light conditions, premium Nikon optical lenses allow you to see clear and bright targets. The measurements are always accurate and true, which ensures that the is also a very high productivity. You no longer need to go back in the field, because you can get the right result at once.
Strong and durable
Trimble C5 Light weight, compact structure, simplified storage, transportation, and setup. It is easy to carry when you work in the field. Users don't feel tired for how long they last. A strong construction means that it can adapt to any situation and to operate anywhere. C5 was constructed to submit excellent results under any condition. You can also expect it to meet high standards, year after year, project after project.
No downtime, and improved the workflow
A fully charged Trimble C5 battery can work all day. If the battery is only half left, it can be hot swappable. So it won't waste any time. Trimble C5 Compatible with the Trimble position tracking technology, L2P. It simplifies the tracking of the devices and gives them a sense of security. The new Trimble C5 has a color touchscreen and supports an on-board Trimble Access. The C5 has a 1 ", 2", 3 ", and 5" accuracy. Whatever the task, it is able to submit high levels of efficiency and productivity, improving the workflow.
This is exactly what you expect from Trimble.
 
 Measurement
Range with specified prisms Good conditions C5 C5 HP
With single prism 2.5in (6.25cm) 16,404 ft (5,000m) 9,843 ft (3,000m)
With reflector sheet 2in*2in (5cm*5cm) 984 ft (300m) 886 ft (270m)
Reflectorless mode C5 Good Normal Difficult
KGC(90%) 2,625 ft (800m) 1,640 ft (500m) 820 ft (250m)
KGC(18%) 1,312 ft (400m) 984 ft (300m) 771 ft (235m)
 
C5 HP Good Normal Difficult
KGC(90%) 1,640 ft (500m) 1,312 ft (400m) 820 ft (250m)
KGC(18%) 1,148 ft (350m) 820 ft (250m) 656 ft (200m)
Accuracy in standard measurement mode   C5  C5 HP
Prism ±(2mm+2ppm) ±(1mm+1.5ppm)
Reflectorless ±(3mm+2ppm) ±(2mm+2ppm)
Measuring interval C5 Standard mode Fast standard mode Tracking mode
Prism mode 1s 0.5s 0.3s
Reflectorless mode 1s 0.5s 0.3s
 
C5 HP Standard mode Fast standard mode
Prism mode 1.6s 1.2s
Reflectorless mode 2.1s 1.6s
Angle measurement
Accuracy
(Standard deviation based on ISO 17123-3)
1″(0.3 mgon), 2″(0.6 mgon), 3″(1.0 mgon), 5″(1.5 mgon)
Reading system Absolute encoder
Circle diameter 2.4in (62mm)
Horizontal/ vertical angle Diametrical/ Single
Telescope
Tube length 5.0in (128mm) 
Image Erect
Magnification 30x (19x/ 38x with optional eyepieces)
Effective diameter of objective Trimble C5 Trimble C5 HP
1.77in (45mm) 1.57in (40mm)
EDM diameter Trimble C5 Trimble C5 HP
1.97in (50mm) 1.8in (45mm)
Field of view 1°25′
Resolving power 3″
Minimum focusing distance 49 ft(1.5m)
Laser pointer Coaxial red light
Tracklight Yes
Reticle illumination Yes, 4 steps
Tilt sensor
Type Dual-axis
Method Liquid-electric detection
Compensation range ±3′
Communications
Communication ports 1 x serial(RS-232C), 2 x USB (host and client)
Wireless communications Integrated bluetooth
Power
Output voltage 3.6V
Full charging time approx. 6h
Operating time   C5 C5 HP
Continous angle-only measurement 14h 19h
Distance/ angle measurement every 30s 12h(AF every 30S) 18h
Continous distance/ angle measurement 7h 10.5h
General specifications
Auto focus Trimble C5 Yes
Trimble C5 HP No
Level vials 10′/ 2mm
Tangent clamps Yes
Display face 1 Color LCD back-lit (640*480 pixel)
Display face 2 Color LCD back-lit (640*480 pixel)
Operating system Windows® embedded compact 7
Processor Dual core 800 MHz
Point memory 512 MB RAM, 4GB flash memory
Internal plummet Optical or class 2 laser
Optical plummet Magnification 3x
Field of view
Minimum focusing distance 0.5m
Dimensions(W*D*H) 8.1in x6.7in x12.5in (206mm x 169mm x 318mm)
Weight(approx.)
1″, 2″, 3″, 5″
Main unit
Trimble C5 9.5lb (4.3kg)
Trimble C5 HP 9.8lb (4.4kg)
Battery 0.2lb (0.1kg)
Carrying case 7.3lb (3.3kg)
Environmental
Operating temperature range Normal -4ºF to 122ºF (-20ºC to 50ºC)
Winterized -22ºF to 122ºF (-30ºC to 50ºC)
Storage temperature range Normal -13ºF to 140ºF (-25ºC to 60ºC)
Winterized -22ºF to 140ºF (-30ºC to 60ºC)
Atmospheric correction Temperature range -40ºF to 140ºF (-40ºC to 60ºC)
Barometric pressure 15.8 inHg to 39.3 inHg(400mmHg to 999mmHg)
or (533hPa to 1,332hPa)
Dust and water production IP66
Certification
Class B part FCC certification, CE mark approval.RCM Mark.
IEC6-825-1 am 2007, IEC6-825-1 am 2014, FDA notice 50
C5 Prism/ Reflectorless mode Class 1 laser
Laser plummet/ Laser pointer Class 2 laser
C5 HP Prism mode Class 1 laser
Reflectorless/ Laser point Class 3R laser
Trimble C5 Engineering Surveying Total Station
Trimble C5 Engineering Surveying Total Station
Trimble C5 Engineering Surveying Total Station
 
Trimble C5 Engineering Surveying Total Station
Trimble C5 Engineering Surveying Total Station
Trimble C5 Engineering Surveying Total Station
 
Trimble C5 Engineering Surveying Total Station
Trimble C5 Engineering Surveying Total Station





 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now